Code
|
Description of Fault |
Reaction |
Comments |
F01
|
Water intake over 4 mins.
|
Restart Possible
|
Water tap off, intake filter blocked, low water
pressure at solenoid valve. |
F02
|
Heater time over 85mins
|
Fatal error, fault stored in the EEPROM.
|
Temperature setting not reached. Faulty heater
circuit. |
F03
|
Pumping Time over 6 mins
|
Fatal error, fault stored in the EEPROM.
|
Water level L1 not reached, sensing unit
blocked, faulty water level controller, faulty or
blocked pump. |
F04
|
Motor not rotating properly
|
Program continues as normal
|
Fault displayed if motor does not start up
before end of program. |
F05
|
Uncontrolled motor start-up
|
After 8 attempts, fatal error, fault stored in
the EEPROM
|
Check in every program position. |
F06
|
Short circuit thermistor (NTC)
|
Fatal error, fault stored in the EEPROM |
Detected when program in Hot water intake or
heating position. |
F07
|
Open Circuit thermistor
|
Fatal error, fault stored in the EEPROM |
Break in wire or faulty component. |
F08
|
Door Open
|
|
Door LED flashes, program halted until door
closed. |
F09
|
Unexpected Heater Function
|
|
|
F10
|
Communication error Indication: program after 11
mins. Test program after 1.5 mins
|
Fatal error, fault stored in the EEPROM
|
No communication between the power and motor
modules. |
F11
|
Over heating at heat dissipater Motor Module:
Fault detected 8 x in succession |
Fatal error, fault stored in the EEPROM
|
Cause: moving parts stiffened up, system
overload, excessive washing load. |
F12
|
Short circuit: motor freewheeling diode |
Fatal error, fault stored in the EEPROM
|
Fault detected 8 x in succession. |
F13
|
Mains voltage too high
|
Fatal error, fault stored in the EEPROM
|
Voltage value greater than 330v. Maximum mains
voltage 253v+/- 10% |
F14 |
Mains voltage too low
|
Fault stored in the EEPROM
|