Make your own free website on Tripod.com

Miele Dishwashers

G686 & G881 Plus - Diagnostics

 
 
Accessing individual program steps (service mode 1)
Enables the engineer to step through a selected program.
 
bulletEnsure door is closed
bulletRotate program selector to the ‘Stop’ position
bulletSwitch appliance ‘Off’
bulletPress & Hold the ‘Delay Start (-)’ & ‘Top Solo’ buttons simultaneously
bulletSwitch appliance ‘On’
bulletThe LCD displays “.” & the ‘Inlet/drain’ led will illuminate
bulletSelect the desired programme (program duration will be shown in LCD)
bulletPress the ‘Start’ button (the reverts to program step display)
bulletPress the ‘Start’ button to advance program manually
bulletIf the ‘Start’ button is not pressed then the program will continue to run automatically.
 
Accessing Test Mode
This test program automatically test all components of the appliance.
 
bulletEnsure door is closed
bulletRotate program selector to the ‘Stop’ position
bulletSwitch appliance ‘Off’
bulletPress & Hold the ‘Delay Start (-)’ & ‘Top Solo’ buttons simultaneously
bulletSwitch appliance ‘On’
bulletThe LCD displays “.” & the ‘Inlet/drain’ led will illuminate
bulletRotate program selector to ‘Position 11’ (Assume program dial is a clock face)
bulletPress the ‘Start’ button.
 
Accessing service mode 2
 
bulletEnsure door is closed
bulletRotate program selector to the ‘Stop’ position
bulletSwitch appliance ‘Off’
bulletPress & Hold the ‘Start’ & ‘Top Solo’ buttons simultaneously
bulletSwitch appliance ‘On’
bulletThe LCD displays “.”the ‘Inlet/Drain’ & ‘Salt’ led’s will illuminate
bulletPress ‘Top Solo’ button to toggle between available options
bulletPress the ‘Start’ button twice to save selected option then switch appliance ‘Off’.
 
Assume program dial is a clock face
 
Program Selector Position Programmable Option LCD Display
1 Fault code display F00 etc
2 Operating hours counter (first 3 digits) 005 etc
3 Operating hours counter (last 3 digits) 123 etc
4 Economy program without electronically controlled water hardness (factory setting) 40
Economy program with electronically controlled water hardness 41
5 Temperature 65°C (factory setting) 50
Temperature 72°C 51
6 With water softener (factory setting) 60
Without water softener 61
7 Water quantity normal (factory setting) 70
Water quantity increased 71
8 Without 2nd interim rinse (factory setting) 80
With 2nd interim rinse 82
9* Turbo-thermic fan run-on time 4/14 min 90
Turbo-thermic fan run-on time 45 min. (in column machine only) 91
* the fan run-on time must be extended to 14 min in the programming mode; otherwise the fan will only run for 14 min even if 45 min are programmed
 
Accessing programming mode
 
bulletEnsure door is closed
bulletRotate program selector to the ‘Stop’ position
bulletSwitch appliance ‘Off’
bulletPress & Hold the ‘Start’ & ‘Delay Start (-)’ buttons simultaneously
bulletSwitch appliance ‘On’
bulletThe LCD displays ‘P00’ or ‘P01’ etc depending on the software version; the ‘Salt’ led will also flash
bulletPress ‘Top Solo’ button to toggle between available options
bulletPress the ‘Start’ button twice to save selected option then switch appliance ‘Off’.
 
Program Selector Position Programmable Option LCD Display
2 Water hardness setting 0-36 (set at 0 when without water softener option is selected in service mode 2) 0-36
9 Turbo-thermic fan run-on time 4 min(factory setting) 9 0
Turbo-thermic fan run-on time 14 min 9 1
Note - if a water softener sensor is fitted there will be no need to programme the water hardness setting.
 
Accessing Fault code display
 
Access service mode 2 selecting Position 1 with the program dial
 
LCD Display Fault
F00 No fault registered
F01 NTC or connections open circuit
F02 NTC or connections short circuit
F03 PCB fault, Selector switch position not recognised
F04 Heating circuit fault
F05 Drainage fault; Heater pressure switch
F06 Water intake fault, too few impulses at start of step
F07 Water intake fault, too few impulses at end of step
F08 Water intake fault, heater pressure switch did not switch on i.e. circulation pump
F09 Heater pressure switch reset at the end of thermostop steps ZT1, ZT2, ZT3 or ZT4
F10 No data transfer between the water softener sensor and EGPL 55x B
F11 No data transfer between the eco sensor and EGPL 55x B
 

To delete fault codes:

bulletPress the ‘Start’ button twice to save selected option then switch appliance ‘Off’
bulletFaults F01, F02, F04 & F09 are indicated by 3 dashes in the LCD at the end of the programme
bulletFaults F10 & F11 flash alternatively in the LCD
 
Note - all programmes can be used until the fault has been removed. For safety reasons the heater will not be switched on during a fault condition.
 

 

 
 