Make your own free website on Tripod.com

 

To find the type of timer used on the appliance inspect rating label. BIT 100 should be displayed.    HOME
Type of Control Programme Selector Programme Buttons Electronic LCD Display Fault Occurred Possible Cause
  LED 1 Programme 3 LED AL01 Overflow in base,has been activated
bulletEnsure lower spray arm support is secure.
bulletCheck whether customer is using both 3in1 tablets and rinse aid. As this causes to much suds.
bulletTurning the pressure switch adjuster ¼ turn Anti – Clockwise reduces water level.
  LED 2 Programme 4 LED AL02 Solenoid valve broken
bulletInlet valve and wiring connections
bulletElement open circuit.
  LED 3 Programme 5 LED AL04 Thermistor circuit
bulletThis thermistor is attached to the Control PCB, therefore the PCB has to be replaced (ensure that correct PCB is ordered there maybe more than one version.)
  LED 4 Programme 6 LED AL08 Time out heating
bulletThermistor detached from casing
bulletCheck position of thermistor. Should be clipped in to top right hand corner of soap dispenser.
bulletReplace Control PCB.
  LEDs 1 and 2 Programme 3 and 4 LEDs AL03 Time out - draining
bulletPump and wiring connections
bulletBlockage
bulletControl PCB
bulletMore than likely to be a blockage, switch appliance on, select program and listen for pump if slight humming noise can be heard, then pump is blocked.
  LEDs 2 and 3 Programme 4 and 5 LEDs AL06 Time out - filling
bulletCheck all plumbing connections
bulletInlet valve
bulletTimer
  LEDs 1 and 3 Programme 3 and 5 LEDs AL05 Filters Blocked
bulletCheck all filters are clean
bulletPressure sensor – this checks the cleanliness of the water. This can be found in the base, plugged into the hose between circulation motor and sump.
  LEDs 1 and 4 Programme 1 and 4 LEDs AL09 Software not recognised
bulletFaulty control PCB
bulletWrong part fitted (ensure correct PCB was ordered.)
  LEDs 2 and 4 Programme 4 and 6 LEDs AL10 Heating element circuit
bulletElement and wiring connections
bulletControl PCB.
  LEDs 3 and 4 Programme 3 and 4 LEDs AL12 Hardware version
bulletControl PCB.
 
Indesit Dishwasher Fault Codes - Dishwashers with 7 Program Options
 
 
The above should be the general layout on the appliance facia.
 
Fault codes will be displayed as a combination of the above LED’s, which will flash repeatedly until appliance is reset. This is done by switching the appliance off, via the On/Off switch and waiting 30 seconds.
 
LED Combinations Fault Occurred Approximate time for fault codes to appear Possible Cause
4 Overflow in base, has been activated 10 seconds
bulletEnsure lower spray arm support is secure
bulletCheck whether customer is using both 3in1 tablets and rinse aid. As this causes to much suds
bulletTurning the pressure switch adjuster ¼ turn Anti – Clockwise reduces water level.
5 Solenoid valve broken 10 seconds
bulletInlet valve and wiring connections
bulletElement open circuit.
6 Thermistor circuit 10 seconds
bulletThis thermistor is attached to the Control PCB, therefore the PCB has to be replaced (ensure that correct PCB is ordered there maybe more than one version.)
7 Time out heating 60 mins
bulletThermistor detached from casing
bulletCheck position of thermistor. Should be clipped in to top right hand corner of soap dispenser
bulletReplace Control PCB.
4 and 5 Time out - draining 4 mins
bulletPump and wiring connections· Blockage
bulletControl PCBMore than likely to be a blockage, switch appliance on, select program and listen for pump, if slight humming noise can be heard, then pump is blocked.
5 and 6 Time out - filling 3 mins
bulletCheck all plumbing connections
bulletInlet valve
bulletTimer.
4 and 6 Circulation Motor not working  
bulletCirculation Motor and wiring connections
bulletStart capacitor
bulletControl PCB.
4 and 5 Software not recognised 10 seconds
bulletFaulty control PCB
bulletWrong part fitted (ensure correct PCB was ordered.)
5 and 7 Heating element circuit 10 seconds
bulletElement and wiring connections
bulletControl PCB.
 
Indesit Dishwasher Fault Codes - Dishwashers with 4 Program Options
 
 
The above should be the general layout on the appliance facia.
 
Fault codes will be displayed as a combination of the above LED’s, which will flash repeatedly until appliance is reset. This is done by switching the appliance off.
 
LED Combinations Fault Occurred Approximate time for fault codes to appear Possible Cause
1 Overflow in base, has been activated 10 seconds
bulletEnsure lower spray arm support is secure
bulletCheck whether customer is using both 3in1 tablets and rinse aid. As this causes to much suds
bulletTurning the pressure switch adjuster ¼ turn Anti – Clockwise reduces water level.
2 Solenoid valve broken 10 seconds
bulletInlet valve and wiring connections
bulletElement open circuit.
3 Thermistor circuit 10 seconds
bulletThis thermistor is attached to the Control PCB, therefore the PCB has to be replaced (ensure that correct PCB is ordered there maybe more than one version.)
4 Time out heating 60 mins
bulletThermistor detached from casing
bulletCheck position of thermistor. Should be clipped in to top right hand corner of soap dispenser
bulletReplace Control PCB.
1 and 2 Time out draining 4 mins
bulletPump and wiring connections
bulletBlockage
bulletControl PCB
bulletMore than likely to be a blockage, switch appliance on, select program and listen for pump, if slight humming noise can be heard, then pump is blocked.
2 and 3 Time out filling 3 mins
bulletCheck all plumbing connections
bulletInlet valve
bulletTimer.
1 and 3 Circulation Motor not working  
bulletCirculation Motor and wiring connections
bulletStart capacitor
bulletControl PCB.
1 and 2 Software not recognised 10 seconds
bulletFaulty control PCB
bulletWrong part fitted (ensure correct PCB was ordered.)
2 and 4 Heating element Circuit 10 seconds
bulletElement and wiring connections
bulletControl PCB.
 
Indesit Dishwasher Fault Codes - Dishwashers with LS 12 – E – 2300 Timer
 
To find the type of timer used on the appliance inspect rating label. BIT 100 should be displayed.
 
Error Code Condition Possible Causes
A01 Machine drains until empty + 1 minute
bulletEnsure lower spray arm support is secure
bulletCheck whether customer is using both 3in1 tablets and rinse aid. As this causes to much suds
bulletTurning the pressure switch adjuster ¼ turn Anti – Clockwise reduces water level.
A02 Machine fills to level and circulation motor runs
bulletOpen/Short circuit
bulletHeater
bulletHeater relay
bulletNTC
bulletSafety thermostat.
A02 Machine fills to level and circulation motor runs
bulletInlet water, temperature too high.
A02 Machine fills to level and circulation motor runs
bulletUpturned dishes above heater causing overheating (Umberalla effect.)
A02 Machine fills to level and circulation motor runs
bulletHalf Load selected but full or large load detected. When ‘Half Load’ is selected only one spray arm will pass water.
A03 Machine drains until level switch resets + 1 minute
bulletOpen/Short circuit NTC.
A04 Machine drains until level switch resets + 1 minute
bulletUnable to detect rise in temperature, within 70 minutes.
A05 Machine drains until level switch resets + 1 minute
bulletPressure switch doesn’t reset
bulletCheck for blockages.
A07 Machine drains until level switch resets + 30 seconds
bulletOpen/short circuit wash pump triac
bulletCheck pump and aqua stop.
A08 Machine drains until level switch resets + 30 seconds
bulletOpen/short circuit auxiliary wash pump triac
bulletCheck wash motor.
A09 Machine drains until level switch resets + 30 seconds
bulletOpen/short circuit main wash pump triac
bulletCheck wash motor.